FrameParserMaxGapFillSamples Property
Gets or sets the maximum gap (in input samples) filled by phase-continued synthesis before resynchronizing.
Namespace: Gemstone.PhasorProtocols.SelCWSAssembly: Gemstone.PhasorProtocols (in Gemstone.PhasorProtocols.dll) Version: 1.0.181 -- Release Build+69c74c3448bebb1c8c739a856f2a43b00db6d500
public int MaxGapFillSamples { get; set; }
Public Property MaxGapFillSamples As Integer
Get
Set
public:
property int MaxGapFillSamples {
int get ();
void set (int value);
}
function get_MaxGapFillSamples();
function set_MaxGapFillSamples(value);
Property Value
Int32
Dropped samples (e.g., lost UDP packets) are inferred from the input timestamp cadence. Gaps up to this size
are coasted by continuing the last phasors at the tracked frequency; larger gaps drop and refill the analysis
window. A negative value means "auto" (one full analysis window); 0 resynchronizes on any gap.